EasyManua.ls Logo

INVT Goodrive 200 - Page 101

INVT Goodrive 200
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive200 inverters Function codes
100
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
frequency is off
0:Save when the power is off
1:Clear when the power is off
LED tens:The action s
election when the other
frequency set frequency is off
0:Save when the power is off
1:Clear when the power is off
P08.48
High bit of
initial power
consumption
P08.49
Low bit of
initial power
consumption
This parameter is used to set the initial
value of the
power comsumotion.
The original value of the power consumption
=P08.48*1000+ P08.49
Setting range of P08.48: 0~59999°(k)
Setting range of P08.49:0.0~999.9°
0.0°
P08.50
Magnetic flux
braking
This function code is used to enable magnetic flux.
0: Invalid.
This inverter can slow down the motor by increasing
the magnetic flux. The energy generated by th
e
motor during braking can be transformed
into heat
energy by increasing the magnetic flux.
T
he inverter monitors the state of the motor
continuously
even during the magnetic flux period.
S
o the magnetic flux can be used in the motor stop,
as well as to c
hange the rotation speed of the motor.
Its other advantages are:
Brake immediately after the stop command. It does
not need to wait the magnetic flux weaken.
The cooling is better. T
he current of the stator other
than the rotor increases during magnetic
flux
braking, while the cooling of the stator is more
effective than the rotor.
0
P08.51
Input power This function
code is used to adjust the displayed
0.56

Table of Contents