Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
●
P05 Group Input terminals
P05.00
0: HDI is high pulse input. See P05.49~P05.54
1: HDI is switch input
0 ◎
P05.01
S1 terminal
function
selection
S2 terminal
function
selection
S3 terminal
function
selection
S4 terminal
function
selection
S5 terminal
function
selection
S6 terminal
function
selection
S7 terminal
function
selection
S8 terminal
function
selection
0: No function
1: Forward rotation
2: Reverse rotation
3: 3-wire control
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Operation pause
9: External fault input
10:Increasing frequency setting(UP)
11:Decreasing frequency setting(DOWN)
12:Cancel the frequency change setting
13:Shift between A setting and B setting
14:Shift between combination setting and A setting
15:Shift between combination setting and B setting
16:Multi-step speed terminal 1
17:Multi-step speed terminal 2
18:Multi-step speed terminal 3
19:Multi- step speed terminal 4
20:Multi- step speed pause
21:ACC/DEC time option 1
22:ACC/DEC time option 2
23:Simple PLC stop reset
0 ◎