EasyManua.ls Logo

INVT Goodrive 200 - Page 72

INVT Goodrive 200
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive200 inverters Function codes
71
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
P05.09
HDI
terminal
function
selection
24:Simple PLC pause
25:PID control pause
26:Traverse Pause(stop at the current frequency)
27:Traverse reset(return to the center frequency)
28:Counter reset
29:Torque control prohibition
30:ACC/DEC prohibition
31:Counter trigger
32:Length reset
33:Cancel the frequency change setting temporarily
34:DC brake
35:Reserved
36:Shift the command to the keypad
37:Shift the command to the terminals
38:Shift the command to the communication
39: Reserved
40:Clear the power
41:Keep the power
42~63:Reserved
0
P05.10
Polarity
selection of
the input
terminals
The function code is used to set the polarity
of the
input terminals.
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT0
BIT1 BIT2 BIT3 BIT4
S1 S2 S3 S4 S5
BIT5
BIT6 BIT7 BIT8
S6 S7 S8 HDI
The setting range:0x000~0x1FF
0x000
P05.11
ON-OFF
filter time
Set the sample filter time of S1~S8 and HDI
terminals. If the interference
is strong, increase the
parameter to avoid the disoperation.
0.010s

Table of Contents

Related product manuals