Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
and the direction is controlled by REV. Sin
natural closed.
3:3-wire control 2; Sin
is the enabling terminal on this
mode, and the running command is caused by SB1
and both of them control the running
direction.NC SB2 generates the stop command.
Note: for the 2-wire running mode, when FWD/REV
terminal is effective, the inverter stop because of the
stopping command from other sources
control terminal FWD/REV keeps effective;
inverter won’t work when the stopping
canceled. Only when FWD/REV
inverter can start again. F
or example, the effective
STOP/RSTstop when PLC signal cycles stop
fixed-length stop and terminal control (see P07.04).
he function code defines the corresponding delay
time of electrical level of the programmable terminals
from switching on to switching off.
0.000s