EasyManua.ls Logo

INVT Goodrive 200 - Page 83

INVT Goodrive 200
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive200 inverters Function codes
82
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
lower limit
P06.24
Upper limit of
AO2 output
100.0%
P06.25
Correspondi
ng AO2
output to the
upper limit
10.00V
P06.26
AO2 output
filter time
0.000s
P06.27
L
ower limit of
HDO output
0.00%
P06.28
Correspondi
ng HDO
output to the
lower limit
0.0kHz
P06.29
Upper limit of
HDO output
100.0%
P06.30
Correspondi
ng HDO
output to the
upper limit
50.00kHz
P06.31
HDO output
filter time
Setting range of P06.23 0.00V~10.00V
Setting range of P06.24 P06.22~100.0%
Setting range of P06.25 0.00V~10.00V
Setting range of P06.26 0.000s~10.000s
Setting range of P06.27 0.0%~P06.29
Setting range of P06.28 0.00~50.00kHz
Setting range of P06.29 P06.27~100.0%
Setting range of P06.30 0.00~50.00kHz
Setting range of P06.31 0.000s~10.000s
0.000s
P07 Group Human-Machine Interface
P07.00
User’s
password
0~65535
T
he password protection will be valid when setting
any non-zero number.
00000: Clear the previous user
s password, and
make the password protection invalid.
After the user’
s password becomes valid, if the
password is incorrect, use
rs cannot enter the
0

Table of Contents

Related product manuals