Goodrive200 inverters Function codes
Name
Detailed instruction of parameters
Default
value
to shift the displayed function code from
right to left.
3: Shift between forward rotations
ress QUICK/JOG to shift the direction of
the frequency commands. This function
in the keypad commands channels.
4: Clear UP/DOWN settings. Press QUICK/JOG to
clear the set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the running commands source. P
QUICK/JOG to shift the running commands source.
7:Quick commission mode(committee according to
the non-factory parameter)
Note: Press QUICK/JOG
and reverse rotation, the inverter does not
record the state after shifting during
The inverter will run according to parameter P00.
during next powering on.
P07.03
P07.06=6, set the shifting sequence of
running command channels.
0:Keypad control→
→communication control
1:Keypad control←→terminals control
2:Keypad control←→communication control
3:Terminals control←→communication control
0 ○
P07.04
Select the stop function by STOP/RST. STOP/RST
is effective in any state for the fault reset.
0:Only valid for the panel control
1:Both valid for panel and terminals control
2:Both valid for panel and communication control
3:Valid for all control modes
0 ○