Goodrive35 inverters Function codes
100
Detailed instruction of parameters
25: Ramp reference frequency
26: Operation speed
Lower
output limit
of AO1
The above function codes define the relative
relationship between the output value and analog
output. When the output value exceeds the range of
set maximum or minimum output, it will count
according to the low-limit or upper-limit output.
When the analog output is current output, 1mA
equals to 0.5V.
In different cases, the corresponding analog output
of 100% of the output value is different. See each
application for detailed information. Please refer to
Analog output in chapter 7 for more details.
Setting range of P06.17:-300.0%~P06.19
Setting range of P06.18:0.00V~10.00V
Setting range of P06.19:P06.17~300.0%
Setting range of P06.20:0.00V~10.00V
Setting range of P06.21:0.000s~10.000s
Setting range of P06.22: -300.0%~P06.24
Setting range of P06.23:0.00V~10.00V
Setting range of P06.24: P06.22~300.0%
Setting range of P06.25:0.00V~10.00V
Setting range of P06.26:0.000s~10.000s
Setting range of P06.27: -300.0%~P06.29
Setting range of P06.28:0.00~50.00kHz
Setting range of P06.29: P06.27~300.0%
Setting range of P06.30:0.00~50.00kHz
Correspon
ding AO1
output of
lower limit
Upper
output limit
of AO1
The
correspond
ing AO1
output of
upper limit
Lower
output limit
of AO2
Correspon
ding AO2
output of
lower limit
Upper
output limit
of AO2