Goodrive35 inverters Function codes
104
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.05
Parameter
s state 1
0x0000~0xFFFF
BIT0:running frequency (Hz on)
BIT1:set frequency(Hz flickering)
BIT2:bus voltage (Hz on)
BIT3:output voltage(V on)
BIT4:output current(A on)
BIT5:running rotation speed (rpm on)
BIT6:output power(% on)
BIT7:output torque(% on)
BIT8:PID reference(% flickering)
BIT9:PID feedback value(% on)
BIT10:input terminals state
BIT11:output terminals state
BIT12:torque set value(% on)
BIT13:pulse counter value
BIT14:length value
BIT15:PLC and the current stage in multi-step speed
0x03F
F
P07.06
Parameter
s state 2
0x0000~0xFFFF
BIT0: AI1 (V on)
BIT1: AI2 (V on)
BIT2: AI3 (V on)
BIT3: HDI frequency
BIT4: motor overload percentage (% on)
BIT5: the inverter overload percentage (% on)
BIT6: ramp frequency given value(Hz on)
BIT7: linear speed
BIT8: AC inlet current (A on)
BIT9~15:reserved
0x000
0
P07.07
Parameter
s for
stopping
state
0x0000~0xFFFF
BIT0:set frequency(Hz on, frequency flickering
slowly)
BIT1:bus voltage (V on)
0x00F
F