Goodrive35 inverters Function codes
105
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
BIT2:input terminals state
BIT3:output terminals state
BIT4:PID reference (% flickering)
BIT5:PID feedback value(% flickering)
BIT6:torque reference(% flickering)
BIT7: AI1 (V on)
BIT8: AI2 (V on)
BIT9: AI3 (V on)
BIT10: HDI frequency
BIT11:PLC and the current stage in multi-step speed
BIT12:pulse counters
BIT13:length value
BIT14~BIT15:reserved
P07.08
Frequency
coefficient
0.01~10.00
Displayed frequency=running frequency* P07.08
1.00
P07.09
Rotation
speed
coefficient
0.1~999.9%
Mechanical rotation speed =120*displayed running
frequency×P07.09/motor pole pairs
100.0
%
P07.10
Linear
speed
coefficient
0.1~999.9%
Linear speed= Mechanical rotation speed×P07.10
1.0%
P07.11
Rectifier
bridge
module
temperatur
e
-20.0~120.0
P07.12
Converter
module
temperatur
e
-20.0~120.0
P07.13
Software
version
1.00~655.35