Goodrive35 inverters Basic operation instruction
180
Function
code
Name
Detailed instruction of parameters
Default
value
8:PROFIBUS/CANopen communication
setting torque
9:Ethernet communication setting torque
10:Reserved
P03.12
Keypad setting torque
-300.0%~300.0%(rated current of the
motor)
10.0%
P03.13
Torque reference filter
time
0.000~10.000s
0.100s
P03.14
Upper frequency of
forward rotation in vector
control
0:Keypad (P03.16 sets P03.14 and
P03.17 sets P03.15)
1: AI1
2: AI2
3: AI3
4:Pulse frequency HDI setting upper-limit
frequency
5:Multi-step setting upper-limit frequency
6:MODBUS communication setting
upper-limit frequency
7: PROFIBUS/CANopen communication
setting upper-limit frequency
8:Ethernet communication setting
upper-limit frequency
9: Reserved
0
P03.15
Upper frequency of
reverse rotation in vector
control
0
P03.16
Keypad setting for upper
frequency of forward
rotation
Setting range:0.00Hz~P00.03
(the Maximum frequency)
50.00Hz
P03.17
Keypad setting for upper
frequency of reverse
rotation
50.00Hz
P03.18
Upper electromotion
torque
0:Keypad setting upper-limit
frequency(P03.20 sets P03.18, P03.21
0
www.barghmaher.ir

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 35 Series and is the answer not in the manual?

INVT Goodrive 35 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive 35 Series
CategoryInverter
LanguageEnglish

Related product manuals