Goodrive35 inverters Function codes
60
Detailed instruction of parameters
command
2: A+B, the current frequency setting is A frequency
command + B frequency command
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B): The bigger one between A frequency
command and B frequency is the set frequency.
5: Min (A, B): The lower one between A frequency
command and B frequency is the set frequency.
Note:The combination manner can be shifted by
P5(terminal function)
When A and B frequency commands are selected as
“keypad setting”, the value of the function code is the
original setting one of the frequency data of the
inverter.
Setting range:0.00 Hz~P00.03(the Max. frequency)
ACC time means the time needed if the inverter
speeds up from 0Hz to the Max. One (P00.03).
DEC time means the time needed if the inverter
speeds down from the Max. Output frequency to 0Hz
(P00.03).
Goodrive35 series inverters define four groups of
ACC/DEC time which can be selected by P05. The
factory default ACC/DEC time of the inverter is the
first group.
Setting range of P00.11 and P00.12:0.0~3600.0s
0: Runs at the default direction, the inverter runs in
the forward direction. FWD/REV indicator is off.
1: Runs at the reverse direction, the inverter runs in
the reverse direction. FWD/REV indicator is on.
Modify the function code to shift the rotation direction
of the motor. This effect equals to the shifting the
rotation direction by adjusting either two of the motor