Ion Technologies Sumpro
®
Battery Back-Up
OPERATION MANUAL
Dated: 08/18/2017
Document Name: SUMPRO_100_OM
Page 10 of 12
www.ionproducts.net
LCD Display Description Remedy
7
Cool Lock OFF:
10 S
The unit has suspended battery
charging because it needs to cool
o󰀨 for a period of time. The display
shows time left before charging start
timer can begin.
Battery charging will
resume after the timer
expires.
8
Fault Lock OFF:
10 S
The unit has entered into a fault
condition and has suspended all
operations. The display shows time
left before operations can begin
again.
Normal operation will
resume after the timer
expires.
9
Sumpro Status
INVERT SUSPENDED
The unit has stopped DC mode due
to a fault condition. Subsequent
screens will state info regarding
suspension.
The underlying fault
condition must clear and
the related lock timer must
elapse.
10
Sumpro Status
FAULTED
The unit has detected a fault
condition and has stopped all
operations until condition clears
and/or necessary time has elapsed
since fault.
The underlying fault
condition must clear and
the related lock timer must
elapse.