8
Insert the power wire into terminal L. Insert the
neutral wire into terminal N. Connect the wires on
RL: insert the load wire in one terminal of RL and the
power wire in the other terminal of RL. Repeat the
operation on the other RLs if you need to use more
switches. If you have a ground wire, put insulating
tape or a hooded terminal to insulate it and place it
into the wall box.
Wire the iotty plate
L N RL3 RL2 RL1
IOTTY
3
Main power supply 230 Vac
= Live/power
= Neutral
= Load/lamp
= Load/lamp
L N RL3 RL2 RL1
3
2
1