At the end of charging with the
electronic battery charger, the
battery does not provide the
correct voltage (about 2.14 V
per element without load) and
only one or a few elements are
found to be discharged when
tested with a hydrometer
(battery models only)
one or more elements are
damaged
replace the damaged
elements if possible.
For 6 or 12 V single block
batteries, replace the entire
battery
The electrolyte in the battery is
turbid (battery models only)
the battery has reached the end
of the charging/discharging
cycles declared by the
manufacturer
• replace the battery
the battery has been charged
with too high a current
• replace the battery
the battery has been charged
beyond the limit suggested by
the Manufacturer
• replace the battery