Defines advisory types: WARNING, CAUTION, NOTICE for hazardous situations and property damage.
Discusses environmental impact of chemicals and responsible refrigerant handling.
Outlines Trane's commitment to responsible refrigerant practices and compliance with Clean Air Act.
Specifies unit types like DX Cooling and DX Cooling with Gas Heat.
Describes efficiency ratings, like Ultra High Efficiency.
Defines airflow configurations, such as Convertible.
Lists cooling capacities from 3 to 10 Tons.
Specifies refrigerant type and coil type (e.g., R-410A, Microchannel).
Details voltage options like 208-230/60/3, 460/60/3, 575/60/3.
Indicates control system, e.g., ReliaTel™ Microprocessor.
Lists heating capacities for different models and types.
Describes fresh air intake options, including economizers.
Specifies supply fan details like VAV and motor type.
Details filter types and access methods.
Describes options for condenser coil protection, like hail guards.
Outlines provisions for through-the-base connections.
Lists options for disconnects and circuit breakers.
Specifies convenience outlet options.
Details communication interface options like LonTalk® and BACnet®.
Describes standard refrigeration system.
Mentions refrigeration controls.
Lists smoke detector options.
Specifies system monitoring controls.
Further details on system monitoring controls.
Details unit hardware enhancements like Stainless Steel Drain Pan.
Lists advanced unit control options.
Provides important notes and clarifications for model number digits and options.
Guides on inspecting the unit upon arrival for damage and verifying nameplate data.
Provides precautions for storing the unit to prevent condensate formation.
Explains the information found on the unit's Mylar nameplate.
Mentions compressor nameplate location and variable speed compressor labeling.
Describes unit features, control systems (electromechanical, ReliaTel™), and compressor staging.
Explains the function and operation of the optional clogged filter switch.
Details the low pressure control input and its effect on compressor operation.
Describes ReliaTel™ control's error handling and lockout for compressor/inverter protection.
Explains the optional condensate overflow switch and its lockout function.
Describes the DLTS function for preventing compressor overheating.
Explains the function of the optional duct-mounted humidity sensor.
Details the economizer control actuator's function and capabilities.
Explains the standard evaporator frost control (Frostat™).
Describes the high pressure control and its lockout function.
Explains the high temperature sensor and its shutdown function.
Details the features and benefits of the optional touchscreen interface.
Explains the low pressure control and its lockout function.
Describes the multiple-zone VAV control for maintaining duct static pressure.
Explains the phase monitor's function and LED indicators for power supply status.
Details the optional power exhaust control.
Explains the programmable zone sensor features and settings.
Describes the optional BACnet™ communications interface.
Explains the use of remote zone sensors for various sensing applications.
Details the features of a remote zone sensor for sensing and timed override.
Explains a remote zone sensor with single setpoint and timed override.
Describes a remote zone sensor compatible with specific remote panels.
Details the LonTalk® communication interface for ICS systems.
Describes the Trane® communication interface for ICS systems.
Explains the RTOM's function in monitoring various unit inputs and functions.
Describes SZVAV and displacement ventilation features.
Explains the optional smoke detector's function and placement.
Discusses zone sensors and thermostats required for RTRM operation.
Details the wall-mounted humidity sensor for dehumidification control.
Explains the wireless zone sensor features and setup.
Describes the ZSM with three system settings and single setpoint.
Details the ZSM with four system settings and dual setpoint capability.
Explains the ZSM with four system settings and status LEDs.
Warns about hazards of fiberglass wool and required PPE.
Lists precautions for handling fiberglass wool, including respiratory and skin protection.
Provides first aid instructions for eye and skin contact with fiberglass dust.
Illustrates minimum operating and service clearances for unit installation.
Illustrates rigging points and center of gravity for lifting the unit.
Provides guidance on creating proper foundations for horizontal unit installations.
Describes supply and return air openings and recommendations for ductwork installation.
Details roof curb requirements for downflow installations, including verification steps.
Provides instructions and warnings for safely rigging and lifting the unit.
Lists essential steps for successful commercial unit installation.
Instructions for ensuring the factory-installed economizer is in operating position.
Explains the usage of temperature limit switches for electric heat units.
Details the process and materials for converting the unit to horizontal discharge.
Describes the factory-installed return air smoke detector and conversion for horizontal discharge.
Explains the factory-installed wireless interface and its conversion for horizontal discharge.
Outlines requirements for main electrical power supply and connections.
Details checks for electric heat power supply and connections.
Outlines requirements for low voltage wiring and thermostat connections.
Details methods for configuring the condensate drain to exit front or base.
Guides on filter quantity, access, and requirements.
Provides guidance on field-installed power wiring.
Covers main unit power supply requirements and standard wiring.
Explains optional wiring through the base electrical option.
Describes the 24-volt control power transformers and their circuit breakers.
Details wiring for DC analog inputs/outputs and conductor sizing.
Explains space temperature averaging using multiple remote sensors.
Explains how to measure and calculate voltage imbalance and its effects.
Details how to check and correct electrical phasing for three-phase motors.
Explains the function of crankcase heaters and oil foaming prevention.
Describes ReliaTel™ control self-diagnostics and test procedures.
Describes different test modes for component operation and troubleshooting.
Explains how to verify proper airflow for unit operation.
Details the unit's operational sequence for different modes and conditions.
Explains unoccupied cooling control without specific panels.
Describes unoccupied heating control without specific panels.
Explains the return air smoke detector's function and air velocity requirements.
Details the economizer startup procedure and minimum position setting.
Provides instructions for starting compressors, including checks and troubleshooting.
Instructions for verifying and setting unit dip switches.
Outlines final checks before leaving the unit after startup.
Lists essential monthly checks for proper unit operation and longevity.
Instructions for inspecting, cleaning, or replacing air filters.
Explains the importance of smoke detector maintenance for proper sampling.
Lists monthly maintenance checks for the cooling season.
Lists monthly maintenance checks for the heating season.
Explains the benefits and process of regular coil cleaning.
Instructions for removing hail guards for coil cleaning.
Warns against using detergents on MCHE coils and recommends specific cleaning methods.
Provides safety warnings and steps for cleaning RTPF coils.
Instructions for reinstalling the hail guard after coil cleaning.
Recommends cleaning and repainting corroded surfaces.
Suggests recording unit data for future reference.
Explains how the RTRM provides unit diagnostics and system status.
Details two methods for checking system status using Zone Sensor Module LEDs or voltage readings.
Provides steps to diagnose system failures by checking voltages.
Lists potential causes and checks for cooling failures.
Outlines checks for service failures like fan issues or clogged filters.
Identifies Emergency Stop activation as a cause for simultaneous failures.
Explains the ZSM SERVICE LED and its indications.
Details various tests for zone temperature sensors and related components.
Details testing serial communication voltage and unit modes.
Explains RTRM default mode operation when input is lost.
Provides temporary operation steps without a zone sensor.
Guides on verifying economizer status using LED indicators and error codes.
Refers to specific documents for compressor inverter drive troubleshooting.
Details warranty for electric air conditioners.
Specifies parts-only warranty for TZC models.
Defines warranty scope for commercial use of models under 20 tons.