Essential safeguards and procedures to prevent injury and damage to equipment or data during operation.
Precautions for using the detector, including daily checks, condensation prevention, and warm-up procedures.
Guidelines for battery handling, charging, storage, and usage to prevent damage and ensure performance.
Defines the manual's coverage and the basis of information, noting potential prototype variations.
Specifies the detector's application for general radiographic diagnosis and its role in replacing film/screen systems.
Defines essential performance criteria linked to risk management for image acquisition and data transmission.
Details patient population, operator qualifications, and the expected product lifetime.
Highlights the importance of patient-detector positioning to mitigate crosstalk effects and prevent image artifacts.
Lists the main components included with the Mars1717VS package.
Provides detailed technical specifications and diagrams for detector components, connectors, and indicators.
Step-by-step instructions for installing the detector panel, including battery and DC power connections.
Guidance on how to correctly install and operate the battery charger.
Specifies the necessary operating system, memory, and firewall configurations for the iDetector software.
Instructions for installing required software components, such as .NET Framework and Visual C++ Redistributable.
Explains connection options like Wireless Client Mode and provides IP configuration examples.
Detailed steps for configuring wired network adapters and IP settings for detector connection.
Comprehensive guide for wireless setup, AP configuration, and network interface settings.
Details the iDetector software interface, including HomePage, Acquire, Detector, Calibrate, and Local Page functions.
Lists potential issues arising from IT network failures that can impact system operation.
Focuses on acquiring X-ray images and the critical need for synchronization with the X-ray generator.
Covers the creation of templates for pre-offset, gain, and defect correction to optimize image quality.
Explains the features for reviewing and uploading images, including local checks and panel uploads.
Provides instructions for updating the detector's firmware using the iDetector software or web interface.
Outlines equipment classification, electrical safety, water ingress protection, and relevant safety standards.
Presents EMI/EMS compliance tables and electromagnetic compatibility requirements for the device.
Details compliance with RF regulations for the USA and European Union, including FCC and EN standards.
Lists international standards applicable to battery safety and transportation.
Provides contact details for the service office, including telephone, fax, email, and physical location.
States the estimated product lifetime of up to 5 years, contingent on regular inspection and maintenance.
Recommends annual inspections and maintenance for patient and operator safety, and device reliability.
Instructions for contacting support for repairs, specifying necessary product information to provide.
Details the availability of main replacement parts for 5 years after production discontinuation.
Contains contact and address information for the manufacturer, iRay Technology Taicang Ltd.
Identifies the authorized European representative, IRAY EUROPE GMBH, for the Medical Device Directive.