Water History Review Feature
17
Water History Review Feature
The Climate Logic system tracks and records the daily adjust-
ment factor for a rolling, two-year period. A one-month snap-
shot is represented by the small bar graph on the Home screen.
The graph is updated daily, and builds from the left to right,
with the most recent day appearing on the left of the scale.
Pressing the % key displays the Water History graph in a
large-scale format. By default, the graph represents the daily
adjustment history for a one-month period. Pressing the ZOOM
key displays the history data in time frames of approximately
2-months, 6-months, 1-year, and 2-years.
Watering history data can also be reviewed in a contextual
format, accessible through the History option of the Utility
Menu. MENU _ UTILITY _ HISTORY.
The History screen lists the date and adjustment % value for
each day in chronological order, with the most recent entry at
the bottom. Use the NEXT and BACK keys to scroll through the
data screens.
Note: Data displayed in the LOGFILE screen is provided for service
use only.
16
Rain/Freeze Sensor Control Feature
Rain/Freeze Sensor Control Feature
When rain or a low temperature condition is detected, system
operation is placed on hold. The Sun icon is replaced with the
corresponding Rain Cloud or Snow Flakes icon. The LED status
indicator is on continuously while the system is on Hold.
When weather conditions improve, the Climate Logic system
automatically resets for normal operation. An adjustable
Dry-out period will prevent automatic watering for 12 hours (by
default) before scheduled watering can resume. The Dry-out
mode is adjustable from 0 to 3 days, in ½-day increments.
To adjust the Dry-out time period, refer to the Dry-out Days
setup procedure on page 14.
Note: To resume watering operation immediately after the reset,
press the BYPASS key to skip the Dry-out mode.
Smart Bypass Mode: While the system is on hold, sensor control
can be toggled Off and On by pressing the BYPASS key. The
Bypass mode will be indicated on the Home screen, and the
LED indicator will blink continuously. Watering operations can
resume, however the Climate Logic system will remain in the
Bypass mode until the system automatically resets after the
Dry-out duration times out.
Note: To resume sensor control mode, press the BYPASS key again
to toggle the Bypass mode O.
CLIMATE LOGIC
MENU
10:15a
Rain Sensor - Bypassed
52F 40%
BYPASS
11/16
CLIMATE LOGIC
52F 40%
Dry Out Remain 12h
MENU
10:15a
BYPASS
11/16
CLIMATE LOGIC
MENU
BYPASS
10:15
a
Rain - No Irrigation
11/16
52F 40%
CLIMATE LOGIC
MENU
BYPASS
3:15a
Cold - No Irrigation
1/10
32F
40%