EasyManua.ls Logo

Irritrol LIFE - Branches; Wire Requirements; Wire specification and quality

Irritrol LIFE
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
IRRITROL Decoder Systems
Branches
The 2-wire can be branched o at any place and in
as many places as desired. Be aware that it may
change the critical path. On a star configuration
it might just be the new farthest point, but on ,a
loop configuration with a branch which loops back
at another point it might prolong the total cable
length. If it is branched o on a loop configuration,
but not looped back, then the branch shall be
treated as a star in respect to the critical path.
3. WIRE REQUIREMENTS
Wire specification and quality
The 2-wire cable shall be jacketed solid parallel wires
for direct burial. It is recommended to use e.g. Paige
P7072D.
Specification of the Paige cable can be found:
http://paigewire.com/products aspx?cat=3&specid= 75#
Similar, but twisted wires can be used.

Related product manuals