ICE CREAM CABINETS
12.1 USER INTERFACE
LED
COMPRESSOR or RELAY 1
ON for compressor on.
Flashing for delay, protection or blocked activation.
DEFROSTING
ON for defrosting in progress.
Flashing for manual activation.
ALARM
ON for active alarm.
Flashing for silenced alarm.
Alarm conditions are always signalled by the buzzer (if present)
and by the corresponding alarm icon LED.
The alarm signal deriving from a faulty probe (probe 1) appears
directly on the instrument display with the indication E1.
The alarm signal deriving from a faulty evaporator probe (probe 2)
appears directly on the instrument display with the indication E2.
FANS
ON for operating fans.