TROUBLESHOOTING 6 – 17
14-3 Battery Under Charging
Step Action Value(s) Yes No
1 Was Visual/Physical Check" performed.
Go to Step 2
Go to
visual/physical
check
2 Inspect the brush contact condition on the generator.
Was there intermittent contact between the brush
and the slip ring?
Repair or
replace the
brush holder
assembly. Go to Step 3
3 Inspect the rotor coil on the generator.
Was there a short circuit in the rotor coil?
Repair or
replace the
rotor coil. Go to Step 4
4 Inspect the stator coil on the generator.
Was there an open circuit or the short circuit on the
stator coil?
Repair or
replace the
stator coil. Go to Step 5
5 Inspect the rectifier on the generator.
Was the rectifier defective?
Replace the
rectifier Go to Step 6
6 Inspect the IC regulator on the generator.
Was the IC regulator defective?
Replace the IC
regulator. Go to Step 7
7 Was the electrical load excessive? Replace more
higher capacity
generator. Go to Step 8
8 Are any DTC stored? Go to indicated
DTC. Solved
14-4 Battery Unstable Charging Current
Step Action Value(s) Yes No
1 Was Visual/Physical Check" performed.
Go to Step 2
Go to
visual/physical
check
2 Inspect the brush contact condition on the generator.
Was there poor contact between the brush and the
slip ring?
Repair or
replace the
brush and/or
the slip ring. Go to Step 3
3 Inspect the rotor coil on the generator.
Was there the short circuit or an open circuit in the
rotor coil?
Repair or
replace the
rotor coil. Go to Step 4
4 Inspect the stator coil on the generator.
Was there an open circuit or the short circuit in the
stator coil?
Repair or
replace the
stator coil. Go to Step 5
5 Inspect the connection between the rectifier and
stator coil on the generator.
Was there a loose connection between the rectifier
and stator coil ?
Repair the
loose
connection. Go to Step 6
6 Inspect the IC regulator on the generator.
Was the IC regulator defective?
Replace the IC
regulator. Go to Step 7
7 Are any DTC stored? Go to indicated
DTC. Solved