SOURce Subsystem(IT-M7700)
Copyright© Itech Electronic Co., Ltd. 50
Chapter 7 SOURce Subsystem(IT-M7700)
The commands in this chapter is a special command of
IT-M7721/IT-M7722/IT-M7723/IT-M7723E, but it’s not suitable for
IT-M7721L/IT-M7722L.
[SOURce:]NORMal:CURRent:RANGe
This command is used to set the current range of the power supply.
Syntax
[SOURce:]NORMal:CURRent:RANGe <0|1|2|AUTO|HIGH|LOW>
Arguments
<0|1|2|AUTO|HIGH|LOW>
Query Syntax
[SOURce:]NORMal:CURRent:RANGe?
Returns
<AUTO|HIGH|LOW>
Note
This command is a special command of IT-M7721/IT-M7722/IT-M7723E.
[SOURce:]NORMal:VOLTage:RANGe
This command is used to set the voltage range of the power supply.
Syntax
[SOURce:]NORMal:VOLTage:RANGe <0|1|LOW|HIGH>
Arguments
<0|1|LOW|HIGH>
Query Syntax
[SOURce:]NORMal:VOLTage:RANGe?
Returns
<0|1|LOW|HIGH>