ReplySET OK
Turn off sleep mode:
SLEEP+user password+space+0
EgSLEEP0000 0
ReplySET OK
18. Set Access Point Name (APN)
Command1 803+user password+space+APN
eg8030000 CMNET
Command2 : 803+user password+space+APN+space+APN user name+space+APN Password
Reply: SET GPRS APN OK
19. Set server IP address and Port
Command 804+user password+space+IP+space+Port
Eg: 8040000 58.64.205.22 8000
Reply: SET SERVER IP AND PORT OK
18. Set Data upload interval time
Command805+user password+Space+X
Eg 8050000 20
Reply: SET OK
Device will upload location to platform every 20 seconds when car acc is on.
Command809+user password+Space+X
X is the location upload interval when car acc off, in the unit of seconds.
Eg 8090000 60
Reply: SET OK
Device will upload location to platform every 20 seconds when car acc is off.
Note : X is mean interval time, the unit is secondsthe wide is 11800
We suggest X be no more than 480 seconds to avoid gprs traffice jam.
Specail Command :
1Reset Command : RESET
2Restart Command RESTART
3Read the current setup information Command: RCONF
5. Track by 900D web based tracking software Setup
Please follow above commands to set ip,port(IP is 58.64.205.22, port 8000), and APN, data
upload interval.
Then please go to http://www1.igpstracking.net/
Enter the user name and password we provided. After log in, please go to “User Center-Asset
Manage”, click “Add