Event ID Event name Event description
1600 Meter - Backflow Intelis Water Meter Extended Alarm bit 9: The meter has detected backflow
consumption. For the International meter this is cleared at midnight each day if the
condition is no longer present. For the NAM meter this is cleared after an “alarm
duration” time which is 1 day minimum.
1601 Meter - Empty
Pipe
Intelis Water Meter Extended Alarm bit 6: The meter has detected that the pipe is
empty. For the International meter this is cleared at midnight each day if the condition
is no longer present. For the NAM meter this is cleared after an “alarm duration” time
which is 1 day minimum.
Is an alarm by default.
1602 Meter - Meter
Reversed
Intelis Water Meter Extended Alarm bit 2: The meter has detected that it has been
installed in a reverse orientation. For the International meter this is cleared at midnight
each day if the condition is no longer present. For the NAM meter this is cleared after
an “alarm duration” time which is 1 day minimum.
1603 Meter Low
Battery
Intelis Water Meter Extended Alarm bit 5: The meter has detected that its battery is
low (NAM Meter remaining life time < 6 months, International Meter remaining life time
< 12 months).
1604 Meter - Leakage Intelis Water Meter Extended Alarm bit 8: The meter has detected a leak. For the
International meter this is set if the average flow rate during each of the previous 24
hours (midnight to midnight) was above the leakage flow rate threshold; it is cleared if
the average flow rate during any of the previous 24 hours (midnight to midnight) was
below the leakage flow rate threshold. For the NAM meter this is set if the average flow
rate during each of the hours over a configurable number of days was above the
leakage flow rate threshold; it is cleared as soon as the average flow rate for an hour
goes below the leakage flow rate.
Is an alarm by default.
1605 Meter - Burst Flow
/ Broken Pipe
Intelis Water Meter Extended Alarm bit 4: The meter has detected a burst flow which
indicates the pipe is likely broken. For both the International and the NAM meter this is
cleared immediately as soon as the condition is no longer present.
Is an alarm by default.
1606 Cover Open / Real
Time Removal
Intelis Water Meter Extended Alarm: The meter has detected that the cover is
currently open.
Is an alarm by default.
1607 Meter - Tamper
Alarm
Intelis Water Meter Extended Alarm bit 11: The meter has detected that the cover was
opened so the meter may have been tampered with. For the International meter this is
never cleared. For the NAM meter this is cleared after an “alarm duration” time which
is 1 day minimum.
Gen5 500WERTModule Remote Installation Guide B Events and Alarms
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 42 of 48