Loading...
Event ID Event name Event description
1608 Meter -
Temperature
Alarm
Intelis Water Meter Extended Alarm bit 0 OR bit 1: The meter has detected that the
temperature has gone outside the meter’s temperature range (either high or low). For
the International meter this is cleared at midnight each day if the condition is no longer
present. For the NAM meter this is cleared after an “alarm duration” time which is 1
day minimum.
3000 Device
Reconfigured
The HES configuration has changed in the device.
3001 Event Log
Cleared
The Itron Event Log has been reset.
3003 Configuration
Downloaded
A new HES configuration has been downloaded.
3004 System Reboot Watchdog error - reboot.
3005 System Restart Planned restart of 500WERTModule.
3006 Improper
Installation
Detected
500WERTModule could not adopt configuration information.
3007 Disconnect
Completed
Disconnect was received and has completed.
3008 Disconnect Failed Disconnect was received but failed to execute. Event detail will contain the verbose_
result attribute of the DisconnectControl object.
3011 Connect
Completed
Reconnect was received and has completed. Event detail will contain the verbose_
result attribute of the DisconnectControl object.
3012 Connect Failed Reconnect was received but failed to execute. Event detail will contain the verbose_
result attribute of the DisconnectControl object.
3013 Flow Restriction
Setting Changed
Restrict / service limit was received and has completed. Event detail will contain the
verbose_result attribute of the DisconnectControl object.
3014 Flow Restriction
Setting Failed
Restrict / service limit was received but failed to execute. Event detail will contain the
verbose_result attribute of the DisconnectControl object.
3015 Authentication
Failed
Application level security failure - authentication.
3016 Access Control
Failed
Application level security failure - access control.
3017 Key Rollover Key rollover command received.
3018 Key Signing Application level security failure - c500WERTModuleificate.
Gen5 500WERTModule Remote Installation Guide B Events and Alarms
December 5, 2022 LDI-0343 REV002 Itron, Inc. Page 43 of 48