ORBIMAT CA | Operating instructions Set-up and assembly
(09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0 27
3. Navigate to the "Service" menu item.
4. Briefly press rotary knob.
The desired selection appears.
Fig. 6: Sub-menu - System Adjustments
5. Select the "Pump water out" menu item.
6. Briefly press rotary knob.
The "Pumping water out" message appears.
The "Cancel" button is highlighted in blue.
Fig. 7: Sub-menu - Service
Fig. 8: Pumping out water
7. Allow water pump to run until the coolant exits the
drain hose under pressure.
8. Confirm "Cancel" by briefly pressing the rotary knob.
The water pump is switched off. The water pump is now
filled with coolant and is ready for operation.