Operation ORBIMAT CA | Operating instructions
58
orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0 (09.03.15) OW_ORBIMAT_CA_BA_871060202_04_EN
Folder tree: This function prints the available structure of
the folders created in the system just like on a PC.
Procedure overview: Here, you are provided with a tabular
overview of all procedures available on the machine,
but without the procedure parameters.
One procedure: Here you must select an individual proce-
dure via the folder structure which is then printed.
Log overview: Prints the tabular overview of all available
procedures.
Fig. 32: Overview of the logs of a procedure
All logs for a procedure: You proceed to a procedure using the folder structure here as well.
One log: You go to a procedure using the folder structure here as well. You are now presented with the overview of all
created logs with this procedure displayed as follows:
Each protocol has a unique number generated when the data record is saved (at the end of the current welding process),
which is comprised of the current date and time.
Example (see Fig.): Log file with the number 20080306 165852 (3/6/08 at 4:58:52 p.m.).
The logs are identified by color:
Green with check:
All measured actual values lie within the monitoring limits for alarm and abort.
Yellow with exclamation mark:
An alarm message is output while welding. The alarm limit values specified in the monitoring limits were undershot or
overshot. The process was not aborted.
Red with X:
Welding was aborted. The monitoring limits were overshot/undershot or the operator initiated a "Stop".
If you now want to print an individual log after viewing it, select it. The machine will print a corresponding log with the
respective active printer (internal or external).
Printing a log directly after welding
If the "direct printing" function is used, the data is not saved. The data is deleted after printing.
The function for saving can also be activated.
To print a log without using a memory card or saving the data, proceed as follows:
X Select the "Yes" option for "Print log files" in the "Welding" status.
Once the process is complete, the log is automatically printed by the active printer.

Table of Contents