9
ENGLISH
USE
PRELIMINARY TESTING
Before each engine startup:
Make sure that the sea water intake valve is open. Dry operation of
the pump would cause in few seconds irreparable damages to the
internal rotor.
Check technical fluids level (fuel, engine oil and coolant).
STARTING AND STOPPING THE ENGINE
For boats equipped with instrument panel not
manufactured by IVECO MOTORS
Startup and stop procedures described below are provided assuming
a genuine IVECO MOTOR instrument panel is assembled on board.
Should the boat be equipped with a customized dashboard which has
been manufactured at the Yard or by the Boat builder, such
procedures may change based on the panel's specific features. In such
cases please observe the Yard's startup/stop sequences and read the
indication instruments as specified in the relevant documentation.
Engines equipped with pre-lubrication electric
system
The pre-lubrication feature is started by acting on the power switch of
the electrical system and the relevant warning light lits up.
The engine startup sequence described in the following pages shall
take place after the required pre-lubrication time has elapsed and the
warning light is turned off.
WARNING!
Before starting up the engine make sure no comburent
vapour or gas is in the engine room.