Troublesymptomandprobablecause Checkingandremedy
3.Hotrearaxle
a.Oilleakbecauseofdamagedsealgasket,loosening
oildrainplug,andjammedventhole,resultininsufficient
lubrication
b.Badlubrication
c.Over-tightenbetweenpinionanddrivengear,over-
tightenonbearing
a.Fillup
b.Replacelubricationaccordwiththeseason
c.Readjust
2.Halfshaftsealleaking
a.Jammedrearaxleventhole
b.Badlubrication
c.Tighteningbetweenpinionanddrivengear,tightbe-
aring,andtighteningonbearing
a.Fillupandreadjust
b.Replacelubricationaccordwiththeseason
c.Readjust
84
OWNER爷SMANUALfor
HFC1061,HFC1063,HFC1083
seriestrucks
7.Steeringmechanismtroubleshooting
Troublesymptomandprobablecause Checkingandremedy
2.Shakeofsteeringwheel,instablesteering
a.Looseningsteeringlinkagemechanism
b.Unbalancedfrontwheel
c.Pendulanttoomuch
d.Damagedgrindingwheel
e.Badlywornortoowideclearanceofsteeringlinkage
mechanism
a.Tightenproperly
b.Balancethewheel
c.Adjust
d.Replace
e.Replaceparts
1.Hardtosteerandsteeringwheelwithbadreturn
a.Distortedmainshaft,slidingshaftorcolumn
b.Looseninguniversaljointorcolumncover
c.Improperrotationofsteeringwheelbearing
d.Insufficientlubricationofsteeringlinkagemechanism
e.Lowpressuretire
a.Replaceparts
b.Replaceuniversaljoint
c.Replaceparts
d.Filluplubrication
e.Inflateproperly
85