18
MANUFACTURER MENU
Access to manufacturer menu is obtained by pressing simultaneously on
, and .
Access code for this menu is (6283). Confirmation by keying
; passing from one parameter to another with confirmation by or .
DISPLAY VALUE UNIT DESCRIPTION
VALUE
RANGES
P01 FRENCH
Language selection
0 = FR 1 = EN
2 = DE 3 = ES
4 = IT
P02 C°
Work unit selection 0 = C° 1 = F°
P03 CORRECTION Probe measurement correction
P04 DIFFERENTIAL 1 °C / °F Temperature differential 1 - 5
SOLENOID Not used
VALVE Not used
P05 R 1 RAPID 50 Sec. Primary rapid agitation period 5 - 250
P06 DEAD TIME 10 Sec. Length of dead time 5 - 250
P07 R 2 RAPID 45 Sec. Secondary rapid agitation period 5 - 250
P08 R SLOW 30 Sec. Slow agitation period 5 - 250
P09 CYCLE 1N 3 Phase 1 cycle number 1 - 7
P10 CYCLE 1 0:20 hh:mm Period between phase 1 cycle agitation 00:20 - 03:00
P11 CYCLE 1 18 Sec. Phase 1 rapid agitation period 5 - 250
P12 CYCLE 2N 3 Phase 2 cycle number 1 - 7
P13 CYCLE 2 0:40 hh:mm Period between phase 2 cycle agitation 00:20 - 03:00
P14 CYCLE 2 10 SEC. Phase 2 rapid agitation period 5 - 250
P15 CYCLE 3 0:50 hh:mm Period between phase 3 cycle agitation 00:20 - 03:00
P16 CYCLE 3 12 Sec. Phase 3 rapid agitation period 5 - 250
P17 SLOW MINIMUM 15 Hz Minimum slow agitation speed 10 - 50
P18 SLOW MAXIMUM 15 Hz Maximum slow agitation speed 10 - 50
P19 RAPID MINIMUM 50 Hz Minimum rapid agitation speed 50 - 100
P20 RAPID MAXIMUM 85 Hz Maximum rapid agitation speed 50 - 100
P21 ACCELERATION 15 Sec. Acceleration ramp 5 - 250
P22 DECELERATION 5 Sec. Deceleration ramp 5 - 250
AGITATION NH Not used
HOLD NH Not used
P23 IPROHIBITED 1:00 hh:mm Rapid agitation prohibited before cooling 00:00 - 01:00