8. Closed Flow Switch on Start-up: Flow switch is non-functional.
Closed or shorted ow switch on system start-up (system disabled).
Contact your authorized dealer or service organization.
9. Frozen on Start-up: Flow switch is non-functional. Shorted ow
switch on system start-up (system disabled) and freeze condition
detected. Contact your authorized dealer or service organization.
10. Cool Warning: Spa water is more than 20°F/11°C cooler than
the temperature set point, the circulation pump and heater will
automatically activate to provide freeze protection. The spa will stay
in this mode until the water temperature reaches 15°F/8°C below the
set temperature. No corrective action is necessary.
Note: The heater icon will be blinking and the error icon will be
displayed under the temperature.
11. Freeze protection: A potential freeze condition has been detected. No
action is required. Jets pump(s) operate until the spa is out of danger.
No corrective action is necessary. If condition persists, contact your
authorized dealer or service organization.
12. Overheat protection: DO NOT ENTER THE WATER! Spa water
temperature is above acceptable limits. Heater is deactivated.
Remove spa cover to speed cooling. Contact your authorized dealer
or service organization.
Note:
As a safety measure, the red lights of the spa will ash on and off as
an indication that the spa is an overheat condition.
The heater icon will be blinking and the error icon will be
displayed under the temperature.
13. Overheat protection: DO NOT ENTER THE WATER! Hi-limit
temperature is above acceptable limits. Heater is deactivated.
Remove spa cover to speed cooling. Contact your authorized dealer
or service organization.
Note:
As a safety measure, the red lights of the spa will ash on and off as
an indication that the spa is an overheat condition.
The heater icon
will be blinking and the error icon will be
displayed under the temperature.
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)
CAUSING SEVERE INJURY, BURNS, OR WELTS.
!

Table of Contents

Other manuals for Jacuzzi J-445

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J-445 and is the answer not in the manual?

Jacuzzi J-445 Specifications

General IconGeneral
BrandJacuzzi
ModelJ-445
CategoryHot Tub
LanguageEnglish

Related product manuals