Page 12
J-400
4.  The electrical supply for this product must include a suitably rated 
switch or circuit breaker to open all ungrounded supply conductors 
to comply with Section 422-20 of the National Electrical Code/USA, 
ANSI/NFPA 70. The disconnecting means must be readily accessible 
to the spa’s occupant but installed at least 5 feet (1.5m) from spa 
water.
5.  The electrical circuit supplied for the spa must include a suitable 
ground fault circuit interrupter (GFCI) as required by NEC Article 
680-42/USA.
6.  To gain access to the spa’s power terminal block, remove the screws 
securing the cabinet panel on the side of the spa under the controls. 
Then remove the four door screws for the small access door on the 
control box (Figure A).
7.  Select the power supply entrance you want to use (Figure A) and 
remove the short cabinet panel from the front of the spa. Make sure 
to install a 3/4" electrical tting and conduit through the large opening 
provided in the bottom of the control box so you can feed the cable 
through to the terminal block.
8.  Connect wires to the terminal block (Figures B-F, pages 13-15). 
ALL WIRES MUST BE SECURELY CONNECTED or equipment 
damage could result!
9.  Install control access box door and reinstall the cabinet side panels.
Figure A 
Equipment Area
4
2
2
5
6
6
8
7
6
3
1
Access Door 
WARNING!
DONOT LOOK AT LIT BULB
SEVERE EYE DAMAGE
OR BLINDNESS CAN OCCUR
9
10
12
11
 
Note: Equipment location (such as pumps, CLEARRAY system, drain, heater etc.) varies 
by model.
1.  J-1000™ Control Box
2.  Power Supply Entrance(s)
3.  Jet Pump
4.  Heater
5.  Spa Drain Valve
6.  Pump Drain Plugs(s)
7.  Jets Pump
8.  Filter/Circulation Pump
9.  CLEARRAY Water Purication 
System
10.  Electronic Ballast (For 
CLEARRAY System)
11.  J-1000 Control Panel
12.  QuickDrain™