The installation of electrical devices and appliances (sockets,
switches, etc.) in bathrooms must comply with the legal require-
ments and standards of each country. In particular, no electrical in-
stallation is permitted within 60 cm of the shower enclosure or at
a height of less than 225 cm
For connection to the electric network of the building, a cable with
a protective sheath having characteristics not inferior to type H 05
VV-F 3x2.5 mm
2
must be used.
The appliance must be powered by a differential cir-
cuit breaker; the operating current must not exceed
30mA.
Parts which contain electrical components, with the ex-
ception of remote control devices, must be placed or
attached in such a way so they do not fall into the tub.
Powered components and appliances must be accessi-
ble to those persons in the tub.
Jacuzzi
®
shower enclosures and "bath/shower combi-
nations" are equipped with a terminal, located on the
frame and identified with the symbol to allow for e-
quipotential connection of the surrounding metal
masses, as required by standards EN 60335.2.60 and
EN 60335.2.105.
ATTENTION! Before carrying out any maintenance
operation, disconnect the appliance from the pow-
er supply line.
0,6 m
0,6 m
2,25 m
31