JIF-2002 WEIGHING INDICATOR&CONTROLLER
24
Batching Weighing
F000
Set ZERO Range
6 digit Zero band value ( Initial ”000.000”)
F101
Batching Mode
1
Customer Programmed Control Mode:
Normal Batching
2
Customer Programmed Control Mode:
Loss-in-Weight Batching
3 Built-in Automatic Program Mode: Normal Batching
4
Built-in Automatic Program Mode:
Loss-in weight Batching
F102
Timer-Comparator Inhibitor
Set between 0.0 to 2.0 Sec ( Initial 0.0 Sec)
F103
Timer-Finish Signal
The finish signal timer can be Set between 0.0 to 9.9 Sec
Initial 0.0 Sec
Finish Signal sent ON at 0.0 Sec. And stays ON until the next
START Signal