JADEVER SCALE
SNUG III
10
. Weight calibration
5-1 List of calibration weights (Please get the standard weighs ready before calibration
pursuant to the stipulated weight)
MODEL SNUG III-150 SNUG III-300
SNUG
III-600
SNUG
III-1500
SNUG
III-3000
on1
50g 100g 200g 500g 1000g
on2
100g 200g 400g 1000g 2000g
on3
150g 300g 600g 1500g 3000g
5-2 Single-point calibration of weight
Specification Display on screen
Procedure
1
Under Stop mode, first hold down button , then
press down button once to energize the
scale, and then release button .
Count
Procedure
2
Press down button to enter calibration mode.
CAL
Procedure
3
First make sure that nothing is on the scale pan, and
then press down button to enter zero
calibration.
Zero
Procedure
4
Perform calibration after on1 is displayed on screen.
On1
Procedure
5
Press down button
to select weights; on1
indicates 1/3 of full capacity, on2 indicates 2/3 of that,
and on3 indicates full capacity. Place the selected
weight on the pan promptly after completing
selection.
On1
On2
On3