MECHANICAL ADJUSTMENT
w
q
e
The highest position of the feed dog should be parallel to the surface of the needle plate.
If not, adjust as follows.
1. Use a hexagonal socket screw (4x6) q.
Insert the hexagonal socket screw (4x6) to the hole w.
Tighten the hexagonal socket screw (4x6) as far as it goes.
2. Loosen the setscrew e (left screw).
3. Turn hexagonal socket screw (4x6) to adjust the feed dog (should be parallel to the surface of the needle
plate).
4. Tighten the setscrew e (left screw).
5. Loosen the hexagonal socket screw (4x6) and remove it.
FEED DOG ADJUSTMENT