External Control (I/O / Fieldbus) 37 DESKTOP ROBOT JR3000
Program Number 128 (#sysIn11)
When ON, this signal enables you to specify program number 128 and higher.
Temporary Stop (#sysIn12, #sysIn16)
You can temporarily stop programs that are running by turning this signal ON. However, you
cannot stop a CP movement while it is running. You can only temporarily stop at PTP points.
Also, when this signal is ON, start is inhibited.
Temporary Stop at Next Point (#sysIn12)
When running a program in External Run Mode, you can temporarily stop at the subsequent
point by turning this signal ON. However, you cannot stop a CP movement while it is running.
You can only stop at PTP points.
If you turn ON the Start (#sysIn1) signal while the Temporary Stop at Next Point (#sysIn12)
signal is ON, 1 point is run.
Program Number 256 (#sysIn12)
When ON, this signal enables you to specify program number 256 and higher.
Program Number 512 (#sysIn13)
When ON, this signal enables you to specify program number 512 and higher.
Program continues
running from here
1 Point Run
Start (#sysIn1)
1 Point Run
Temporary Stop at Next
Point (#sysIn12)