External Control (I/O / Fieldbus) 72 DESKTOP ROBOT JR3000
7.4.4
Settings
Settable Items Setting/Selection Range Function
Station Number 1 – 64 You can set station numbers 1 – 64. The CC-
Link remote device station is distinguished
by its station number. If you are connecting
multiple slaves, choose and set available
station numbers.
Transmission
Speed
Specification
156 kbps
625 kbps
2.5 Mbps
5 Mbps
10 Mbps
If you increase the transmission speed, the
transfer distance is shortened.
156 kbps 1200 m
625 kbps 900 m
2.5 Mbps 400 m
5 Mbps 160 m
10 Mbps 100 m
Version Number 1
2
Compatible with two CC-Link versions: Ver.1
and Ver.2.
Stations
Occupied /
Expansion Cyclic
Settings
1 Station Occupied / Expansion
Cyclic Setting x1
2 Stations Occupied /
Expansion Cyclic Setting x1
3 Stations Occupied /
Expansion Cyclic Setting x1
4 Stations Occupied /
Expansion Cyclic Setting x1
1 Station Occupied / Expansion
Cyclic Setting x2
2 Stations Occupied /
Expansion Cyclic Setting x2
1 Station Occupied / Expansion
Cyclic Setting x4
1 Station Occupied / Expansion
Cyclic Setting x8
Word number input and word number output
are decided the same as the tables below
depending on the settings for the occupied
stations and the expansion cyclic settings.
NOTE:
Expansion cyclic settings 2, 4, 8 are
only compatible with Ver. 2.