External Control (I/O / Fieldbus) 73 DESKTOP ROBOT JR3000
1 Station Occupied/Expansion Cyclic Setting x1
Number Register Number Relay Number
Data Input 4 100 – 103 -
I/O Input
16
- 1400 – 140F
Data Output 3 180 – 182 -
I/O Output
16
- 1C00 – 1C0F
2 Stations Occupied/Expansion Cyclic Setting x1
Number Register Number Relay Number
Data Input 8 100 – 107 -
I/O Input 32 - 1400 – 141F
Data Output 7 180 – 186 -
I/O Output 32 - 1C00 – 1C1F
3 Stations Occupied/Expansion Cyclic Setting x1
Number Register Number Relay Number
Data Input 12 100 – 10B -
I/O Input
48
- 1400 – 142F
Data Output 11 180 – 18A -
I/O Output
48
- 1C00 – 1C2F
4 Stations Occupied/Expansion Cyclic Setting x1
Number Register Number Relay Number
Data Input 16 100 – 10F -
I/O Input
64
- 1400 – 143F
Data Output 15 180 – 18E -
I/O Output
64
- 1C00 – 1C3F
1 Station Occupied/Expansion Cyclic Setting x2
Number Register Number Relay Number
Data Input 8 100 – 107 -
I/O Input 16 - 1400 – 140F
Data Output 7 180 – 186 -
I/O Output 16 - 1C00 – 1C0F
2 Stations Occupied/Expansion Cyclic Setting x2
Number Register Number Relay Number
Data Input 16 100 – 10F -
I/O Input
48
-
1400 – 142F
Data Output 15 180 – 18E -
I/O Output
48
- 1C00 – 1C2F