External Control (I/O / Fieldbus) 120 DESKTOP ROBOT JR3000
10.7
Input Signals
If connecting a two-wire external device, such as a sensor, use one which has a leakage current
of no more than 0.3 mA. If you use a device with a leakage current of more than 0.3 mA, it may
not turn OFF.
Caution
Do not assign wiring other than the wiring specified above.
Assigning the wrong wiring can damage the internal circuits.
External Power Supply DC 24 V
External Power Supply DC 24 V
INPUT
COM-
(GND)
COM+
(DC 24 V)
5.6k
#MT1
Input18
#MT2
PNP
Input18
#MT1
Input18
#MT2
Input18

Table of Contents