2. The discharging electrode is oxidized or the distance is too long, pls remove
oxidized film or adjust the distance to 1mm.
3. Individual component of high frequency arc starting circuit is damaged, find it
and replace it.
4. The manual argon welding transfer switch is damaged.
1. It may be caused by over-current protection, pls turn off the machine and restart
it after the indicator extinguishes, and the machine will operate normally.
2. It may caused by over-heat protection, do not turn off the machine, and wait
around 2-3 minutes, and the machine will operate normally.
3. It may caused by inverter circuit failure. Unplug the power terminal of master
transformer on the MOS board(near the VH-07 inserter), and restart the
machine.
a) if the abnormal indicator remains lighting, turn off the machine and unplug
the power terminal of high frequency arc starting power supply (near the
VH-07 inserter), and restart the machine.
i. Individual MOFSET on MOS board is damaged if the abnormal
indicator remains lighting.
ii. The voltage increasing transformer of high frequency arc starting
circuit in power supply board is damaged if the abnormal indicator
does not light.
b) Connect the power cord of failed inverter, and unplug the power cord of
master transformer, and restart the machine :
i. If the abnormal indicator does not light, the transformer on middle
board may be damaged. Pls check the primary inductance and Q
value with bridge circuit.
ii. The double-times rectifier of middle board may be broken through
individually, pls find it and replace it with a same model one.
4. It may be caused by short circuit in the feedback circuit.