22
OPERATION - TIG
Before starng any welding acvity ensure that you have suitable eye protecon and
protecve clothing. Also take the necessary steps to protect any persons within the welding
area.
TIG operaon steps
Select the DC TIG mode by pressing the welding mode selecng key.
Select the 2T mode by pressing the operaon mode selecng key.
Select the pre ow me seng funcon by
pressing the parameter selecng key unl the
T pre LED illuminates. The pre ow me range
is 0~15 seconds and is adjusted via the control
knob and the pre ow me is shown on the
front panel digital display.
Select the inial current seng funcon by
pressing the parameter selecon key unl the
Is LED Illuminates. The inial current range is
0~60amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The inial current
amperage can be adjusted during welding.
Select the upslope me seng funcon by
pressing the parameter selecon key unl the
Tup LED Illuminates. The upslope me range is
0~10 seconds and is adjusted via the control
knob and the me is shown on the front panel
digital display.
Select the peak current seng funcon by
pressing the parameter selecon key unl the
Ip LED Illuminates. The peak current range is
5~300amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The peak current
amperage can be adjusted during welding.