24
OPERATION - TIG
Before starng any welding acvity ensure that you have suitable eye protecon and
protecve clothing. Also take the necessary steps to protect any persons within the welding
area.
TIG operaon steps
Pulsed TIG - Connued
Select the peak current seng funcon by
pressing the parameter selecon key unl the
Ip LED Illuminates. The peak current range is
5~300amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The peak current
amperage can be adjusted during welding.
Select the base current seng funcon by
pressing the parameter selecon key unl the
Ib LED Illuminates. The base current range is
5~300amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The base current
amperage can be adjusted during welding.
Select the downslope me, crater current and post ow gas me as standard TIG.
Select the pulse duty cycle seng funcon by
pressing the parameter selecon key unl the
% LED Illuminates. The pulse duty range is
10~90% and is adjusted via the control knob
and the percentage is shown on the front
panel digital display. The pulse duty cycle can
be adjusted during welding.
Select the pulse frequency seng funcon by
pressing the parameter selecon key unl the
Hz LED Illuminates. The pulse frequency range
is 0.5~500Hz and is adjusted via the control
knob and the frequency is shown on the front
panel digital display. The frequency can be
adjusted during welding.
Select the spot me seng funcon by
pressing the parameter selecon key unl the
Tspot LED Illuminates. The spot me range is
0.1~10 seconds and is adjusted via the control
knob and the me is shown on the front panel
digital display.