We thank you for choosing Jayline and welcome you among the
many happy Jayline customers. Please keep this booklet as a
reference guide.
Installation of Jayline Solid Fuel Heater
Please follow carefully all dimensions and recommendations provided on the individual
specification sheet for your model of heater. These dimensions comply with the required
standards of New Zealand (AS/NZS 2918:2001).
As building and safety standards vary for wood heaters please check with your local
building inspector or local authority prior to installations as a permit may be required.
Jayline recommends you use a qualified solid fuel heater installer or a registered plumber
to install your woodstove. Your dealer or heating specialist should be able to help with
recommendations.
INSTALLATION – FREESTANDING MODELS
1 Unpack the heater and check for any transport damage.
2 Inspect the outside of the building to ascertain the point of roof penetration for the
flue system. If a flue system is built and installed to the correct height it will
normally prevent downdraught problems during windy weather and eliminate
smoke spillage problems due to lack of draught.
3 Check suitable siting for appliance and size of floor protector. Ensure position of
the flue pipe and, if possible, enter the ceiling space to check that no major
structural members will be affected by the flue pipe path.
4 Check that the sub-structure is capable of carrying the heater (i.e. weight
consideration on the floor).
5 Check measurements of the heater to combustibles or shield.
6 Locate the heater in the required position (also see ‘Fitting Seismic Restraint’
after installation instruction #14).
7 Using a plumb line, mark the flue penetration hole in the ceiling using a thin nail
driver through the ceiling.
8 Cut the square ceiling hole to the required size and frame out.
1-05-06