EasyManua.ls Logo

JAYLINE SS280 - Page 3

Default Icon
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOVEMBER 2012 page 3www.jayline.co.nz
Flue exiting more than 3 metres from the ridgeline must terminate no less than 1 metre above the
roof penetration (see diagram 1 below).
Where the top of the ue pipe is more than 2 metres above its highest xing point, it must be stayed
against high winds.
9. Drill and x ue system into ue spigot with stainless steel self-tapping screws.
10. Drill and secure the appliance to the oor protector using the two holes in the rear legs of the
appliance.
FITTING SEISMIC RESTRAINT
The Floor Protector must be mechanically xed to the oor by bolting or screwing. Note: Floor Protector
to be xed by gluing when on a concrete oor that may have water pipes or electrical wires present. The
appliance can then be bolted to the oor protector with two 6mm x 50mm dynabolts.
BAFFlE
Before lighting your appliance for the rst time, make sure the bae is in the correct position being as
far to the rear as possible.