UV Clarifier - Electrical Connection
Please read safety instructions before plugging the unit into the electrical outlet.
When working, a purple UV light can be seen through the viewing window located in the UV housing.
An operational test can only be carried out when the equipment is fully assembled. Do not test the UV
while the screw cap is off the unit.
Seasonal Use
Summer: The unit should remain in operation 24 hours a day.
Winter: It is recommended to store the unit in a frost-free location.
Maintenance and Care
When carrying out any maintenance, the unit must be disconnected from the electrical circuit.
Clean the unit at least twice a year. A clean quartz tube will allow the UV light to be more effective in
controlling algae. More frequent cleaning may be required for ponds with severe algae growth. Tip: Use
warm vinegar to wipe the quartz sleeve for a faster clean and efficient removal of mineral build up.
WARNING: Do not allow water to come in contact with the electrical socket or bulb.
To Disassemble
Always remove inlet and outlets by unscrewing the hose couplings. Drain the unit before cleaning.
Carefully dismantle the unit by first unscrewing the screw cap and two wall brackets, then separate the
outer housing and removing the quartz tube.
To Reassemble
Be sure that the inside of the quartz sleeve is completely dry prior to reassembly.
When reassembling, ensure that the sealing rings are properly seated (lubricate with a small amount of
silicone lubricant/grease if necessary).
Replacement of UV Clarifier Bulbs
2G11 base 36w UV Clarifier Bulb should be replaced once every 6-12 months of operation.