EasyManua.ls Logo

Jegs 81553 - Parts Washer Assembly

Default Icon
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Assembly
1. Remove machine from packaging and inspect for any visual damage.
2. Remove parts inside the machine.
3. Lay clean hard cardboard on the floor and lay machine on its lid. Make sure you hold cover
closed when laying machine on its lid.
4. Mount four legs on brackets with M6 x 12 Philips head screws and M6 nuts. NOTE: DO NOT
TIGHTEN.
5. Place lower shelf between legs with flat surface up and attach to legs with M6 x 12 Philips head
screws and M6 nuts.
6. With legs pressed tight against lower shelf, tighten all screws to lower shelf.
7. Tighten all the screws installed in step 4.
8. Stand machine up. Be careful to hold lid closed.
9. Put work shelf and basket into the machine.
10. Mount pump assembly into slot on the side of the machine then place filter screen in position.
11. Plug machine into standard 115Volt/ 60Hz grounded outlet and fill with proper amount of fluid.
12. Turn switch on. Fluid should now be flowing from the flexible spigot.
SPECIFICATIONS
Recirculating Parts Washer
Overall Dimensions
45.28 x 22.05 x 35.43
Tank Dimensions
44.69 x 21.46 x 12.6
Max Solvent Capacity
40 Gallons
Max Pump Output Through Spigot
5.28 gpm
Electrical Requirements
115V/60Hz/O.5A
Gross Weight
99.21 lbs.
1-800-345-4545 jegs.com