Function and Principle
The VAC Controller is programmed to control the following:
Automatic start and stop of a Vacuumarator™ pump.
Manual start and stop of a Vacuumarator™ pump.
Vacuum level monitoring.
Auto stop after delayed run time (default 10 min).
Tank level monitoring from a level switch in a tank.
Activation of an alarm signal.
Ready signal from a presence sensor (optional). Starts the Vacuumarator™ pump and produces vacuum to a set vacuum level.
Alarm
The VAC Controller is programmed with the following alarm settings:
Power ON - Engages closed contact at alarm output F.
Low Vacuum - Engages and activates alarm output G.
Full Tank - Alarm is based on a level indication from a tank. Requires a level switch (not included).
Long Running Time - Engages and activates alarm output I.
Vacuum Transmitter Fault - Alarm is based on vacuum transmitter not connected, connected wrong, not working.
Full Tank Warning - If the time setting in "runtime after full tank" has been set over 00, a pre-warning alarm will sound. This means that the
pump will run in xx-minutes before the full tank alarm sounds. Start planning to have the tank emptied.
Operation
AUTO Mode 1.1
When the system is intended to be used as a constant vacuum system (CVS), and the motion/presence sensors are not connected to the
VAC Controller.
VIP Mode 1.2
When the system is used with motion/presence sensors that are connected to the VAC Controller. Vacuum is produced when activating the
zone of the motion sensor.
Manual Mode 1.3
Starts and stops the Vacuumarator™ pump via the VAC Controller, regardless of the vacuum transmitter (vacuum level).
WARNING: This can cause the vacuum to reach a very high level in the system and the pump will not stop.
OFF Mode 1.4
System OFF, the VAC Controller will not start in this mode.