Page #6 background imageLoading...
Page #6 background image
XALIS
6
Entrée / Input
Sorties / Outputs
COURANT (continu)
CURRENT (dc)
Echelles standards : 0-1mA; 0-10mA;
4-20mA; +/-1mA; +/-10mA; +/-20mA
Standard scales : 0-1mA; 0-10mA;
4-20mA; +/-1mA; +/-10mA; +/-20mA
Echelle réglable : De -22mA à 22mA
Adjustable scales : From 0mA to 22mA
TENSION (continue)
VOLTAGE (dc)
Echelles standards : 0-100mV; 0-1V; 0-5V;
1-5V; 0-10V; 2-10V; 0-50V; 0-100V; 0-250V;
0-500V; 0-1000V
+/- 100mV; +/-1V; +/-5V; +/-10V +/-50V ;
+/-100V ; +/-250V; +/-500V; +/-1000V
Echelles réglables : De -110mV à +110mV
De -2V à 11V, de -1000V à 1000V
Standard scales : 0-100mV; 0-1V; 0-5V;
1-5V; 0-10V; 2-10V; 0-50V; 0-100V; 0-250V;
0-500V; 0-1000V
+/- 100mV; +/-1V; +/-5V; +/-10V +/-50V ;
+/-100V ; +/-250V; +/-500V; +/-1000V
Adjustable scales : From -110mV to +110mV
From -2V to 11V, from -1000V to 1000V
SONDE RESISTANCE
VARIABLE
RTD
PT10 ; PT1000 ; Ni100 ; Ni1000
2 ou 3 fils,
PT100 3 ou 4 fils
C50, Cu53, Cu100
PT10; PT100 ; PT1000 ; Ni100 ; Ni1000
2 or 3 wires
PT 100 3 or 4 wires
C50, Cu53, Cu100
THERMOCOUPLE
THERMOCOUPLE
J, K, T, B, R, S, E, NiMo, N, W3/C,
W5/D, P
J,K, T, B, R, S, E, NiMo, N, W3/C,
W5/D, P
POTENTIOMETRE
POTENTIOMETER
De 470Ω à 100KΩ
From 470Ω to 100KΩ
ALIMENTATION
CAPTEUR
SENSOR POWER
SUPPLY
Capteur 2 ou 3 fils 24V - 36mA max
Sensor 2 or 3 cords 24V - 36mA max
RESISTANCE
DEUX FILS
2 WIRES RESISTOR
1KΩ - 5KΩ - 10KΩ- 50K
Permet la réalisation de courbe PTC et NTC
1KΩ - 5KΩ - 10KΩ- 50K
Allows achievement of curve PTC and NTC
TENSION
CURRENT
Echelles standards: 0-10V ; 0-5V ; 1-5V ; 2-10V
Echelle réglable : De 0 à 11V
Standard scales :0/10V ; 0/5V ; 1/5V ; 2/10V
Adjustable scale : From 0 to 11V
SORTIE
2 RELAIS
SORTIE
4 RELAIS
2 RELAYS
OUTPUTS
4 RELAYS
OUTPUTS
XALIS 9200U0 - X A L I S 9200U1
2 Relais 1RT - 2A -250Vac
XALIS 9200U0 - X A L I S 9200U1
2 Relays 1 MO & MC - 2A -250Vac
XALIS 9400U1 - XALIS 9400U2
4 Relais 1RT - 2A -250Vac
XALIS 9400U1 - XALIS 9400U2
4 Relays 1 MO & MC - 2A -250Vac
SORTIE
ANALOGIQUE
ANALOGUE
OUTPUT
XALIS 9000U1 - XALIS 9200U1
XALIS 9400U1 - XALIS 9400U2
XALIS 9000U1 - XALIS 9200U1
XALIS 9400U1 - XALIS 9400U2
COURANT
Echelles standards: 0-10mA; 0-20mA ; 4-20mA
Echelle réglable : De 0mA à 22mA
Standard scales : 0-10mA; 0-20mA ; 4-20mA
Adjustable scale :
from 0mA à 22mA
CURRENT
XALIS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JM Concept XALIS 9200U1 and is the answer not in the manual?

JM Concept XALIS 9200U1 Specifications

General IconGeneral
BrandJM Concept
ModelXALIS 9200U1
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals