8-gallon Air Compressor Kit
58-7992-0
Instruction Manual
For Parts, Service, Warranty or other Assistance, please Call 1-877-888-3872
Manual 58-7992 V 1.7– 8 Gallon compressor
2005-7-19

Questions and Answers

  • A
    Andrew SandovalAug 2, 2025
    Why does my jobmate Air Compressor pressure relief valve keep opening?
    • I
      Isabel SmallAug 2, 2025
      The pressure relief valve on your Jobmate Air Compressor might be opening because the tank pressure has exceeded the normal operating pressure or the pressure switch is stuck. In both cases, the suggested solution is to replace the pressure switch.
  • H
    heidi72Aug 14, 2025
    What to do if jobmate 58-7992-0 Air Compressor is overheating?
    • S
      sandra88Aug 14, 2025
      If your Jobmate Air Compressor is overheating, relocate it to an area with cool, dry, and well-circulated air. Also, clean all cooling surfaces of the pump and motor thoroughly, and replace any worn parts, reassembling with new seals.
  • J
    Jennifer PowellAug 21, 2025
    How to fix excessive starting and stopping of jobmate Air Compressor?
    • K
      Kevin MooreAug 21, 2025
      To address excessive starting and stopping of your Jobmate Air Compressor, check fittings for leaks using soapy water, and tighten or reseal any leaking fittings, being careful not to overtighten. Replace any worn parts, reassembling with new seals, and replace any faulty seals. Note that some starting and stopping is normal. If the pressure drops too low, adjust the regulator while using the accessory. Check the air requirement of the accessory. If it is higher than the CFM and pressure supplied by the compressor you need a larger compressor. Most accessories are rated at 25% of actual CFM while running continuously. If the problem persists, consult an electrician.
  • E
    Eric OwensAug 27, 2025
    How to troubleshoot low pressure, not enough air and continuous running jobmate Air Compressor?
    • P
      Paula JonesAug 27, 2025
      To troubleshoot low pressure, insufficient air, or continuous running in your Jobmate Air Compressor, close the valve and decrease usage. Check the air requirement of the accessory. If it is higher than the CFM and pressure supplied by the compressor, you need a larger compressor. Most accessories are rated at 25% of actual CFM while running continuously. Remove and clean or replace the air hose, checking for holes and replacing if necessary. Replace the tank immediately if needed, without attempting repairs. Replace any faulty seals, and replace worn parts, reassembling with new seals.
  • D
    Daniel KellyNov 7, 2025
    What to do if my jobmate 58-7992-0 motor will not run?
    • T
      Tyler JohnsonNov 7, 2025
      If your Jobmate Air Compressor motor isn't running, there are several potential causes: * The tank pressure might exceed the preset pressure switch limit. In this case, the motor will start automatically when the tank pressure drops below the kick-in pressure. * The motor overload protection might have been tripped. Allow the motor to cool off; the overload switch will reset automatically, which may take several minutes. * A fuse might be blown, or a circuit breaker tripped. Replace the blown fuse or reset the circuit breaker, ensuring you don't use a fuse or circuit breaker with a higher rating than specified for your circuit branch. A 'Fusetron' Type T fuse is acceptable. * Check for low voltage and discontinue the use of an extension cord. * Disconnect other applications from...

Summary

Safety Guidelines and Definitions

Hazard Warnings

Critical safety alerts covering chemical exposure, rupture risks, and potential physical injuries.

Rupture Risk

Dangers of tank weakening due to rust, modifications, or exceeding pressure limits.

Risk of Eye or Head Injury

Hazards from propelled objects or compressed air streams causing eye or head trauma.

Risk of Fire or Explosion

Ignition risks from sparks, flammable materials, and exceeding pressure limits.

Risk of Hearing Loss

Potential for permanent hearing damage from prolonged exposure to compressor noise.

Risk of Injury

General risks from accidental activation, propelled fasteners, and tool misuse.

Risk of Electric Shock

Dangers of electrocution from water, faulty wiring, or contact with live metal parts.

Risk of Entanglement

Hazards from loose clothing or jewelry getting caught in moving parts.

Risk of Cuts or Burns

Risks from cutting tools and hot compressor components like pump and manifold.

Precautions

Draining Moisture

Daily draining of tank moisture to prevent corrosion and freezing issues.

Ventilation and Placement

Proper positioning for cooling and airflow, maintaining clearance from walls.

Secure Transport

Fastening the unit and releasing pressure before moving it.

Cord and Hose Protection

Protecting the air hose and electric cord from damage and regular inspection.

Basic Air Compressor Components

Assembling the Compressor

Compressor Controls

Pressure switch

Controls compressor ON/OFF operation, manual and automatic modes.

Pressure Relief Valve

Prevents over-pressurization by automatically opening at preset levels.

Tank Pressure Gauge

Displays the air pressure level stored within the tank.

Air Pressure Regulator

Allows adjustment of line pressure to suit the connected tool.

Regulated pressure gauge

Shows the output pressure after regulation.

Regulated pressure quick connect coupler

Connects air hoses to the regulated outlet pressure.

Electrical Power Requirements

Extension Cord

Grounding Instructions

Breaking in the Pump

Operating Instructions Daily Startup

Shutdown

Maintenance

Draining the Tank

Procedure for draining condensation from the tank to prevent corrosion.

Checking the Relief Valve

Daily check of the pressure relief valve for proper function and obstructions.

Testing for Leaks

Method for detecting air leaks in hoses and connections using soapy water.

Storage

Instructions for cleaning, draining, and protecting the compressor for long-term storage.

Service

Recommended periodic maintenance tasks, including daily checks.

Troubleshooting

Low pressure; Not enough air

Issues related to insufficient air pressure or volume and their resolutions.

Compressor does not stop

Diagnosing why the compressor fails to shut off automatically.

Excessive starting and stopping while not in use

Causes and solutions for frequent cycling of the compressor.

Circuit breaker;fuse trips

Troubleshooting tripping circuit breakers or fuses due to voltage drop or overload.

Overheating

Identifying causes of overheating and methods for cooling the unit.

Motor Stalls

Reasons for motor stalling, such as leaks, low voltage, or defective valves.

Pressure relief valve opens

Causes for the pressure relief valve opening unexpectedly.

Motor will not run

Troubleshooting steps when the compressor motor fails to start or run.

Check valve stuck open

Resolving issues with check valves or bleeder valves causing pressure loss.

Compressor attached to extension cord

Problems arising from using extension cords and recommended actions.

Glossary of Terms

Limited Warranty

Parts List

jobmate 58-7992-0 Specifications

General IconGeneral
Power SourceElectric
TypePortable
CFM at 90 PSI2.6 CFM
Voltage120 V
Tank Capacity6 gallons