■ SSL network encryption from the unit to the GCM
■ IPv4 and IPv6 network protocols
■ 802.1X port-base authentication
■ HTTPS Web-based configuration
■ Offline mode for two readers that allows the last 1,000 previous card admits and/or a specific personnel group of no
more than 100
Table 1:Part numbers and descriptions of IP-ACM Ethernet Door Module v2 and enclosures
Part Number Description
IP-ACM2A-MB IP-ACM V2, 2 Reader, board only
IP-ACM2A-EM IP-ACM V2, 2 Reader in metal enclosure
IP-ACM2A-EP IP-ACM V2, 2 Reader in plastic enclosure
IP-ACM2-CAN IP-ACM metal enclosure without board
IP-ACM2-CAN-P IP-ACM plastic enclosure without board
IP-ACM2A-MB-5PK IP-ACM V2, 2 Reader, board only five pack box
Requirements and Specifications
The contents of this chapter explain the installation, power and wiring, grounding, and environmental requirements for
the IP-ACM v2.
Installation Requirements
Ensure the site is ready:
■ The module installation must be performed by a certified installer and must be installed within the same protected
premise as the controlling GCM.
■ For a UL-compliant installation, the power supply must be UL Listed to UL 294 and UL 603, low voltage Class 2
power limited with appropriate ratings.
Table 2: UL 294 Levels
Feature Level
Destructive Attack 1
Line Security 4
Endurance 4
Standby Power 1
■ All interconnecting devices must be UL Listed, low voltage Class 2 power limited.
■ The site must be approved and all wiring must comply with UL requirements and other codes, as appropriate.
Installation shall be in accordance with the National Electric Code, ANSI/NFPA 70-1993.
■ In this installation, the enclosure is mounted directly to a wall or uni-strut using suitable user-supplied hardware.
2